          CP series low frequency online UPS 10 ~ 600kVA

          Product profile

          The CP series UPS has high reliability, anti-interference ability, high fault tolerance, lightning protection, high surge resistance, strong overload capacity and other characteristics. The rated capacity ranges from 10 to 600kVA. This series of products can be used in parallel, hot backup or standalone, and is suitable for data centers in banks, securities and other institutions, as well as industries such as communication, transportation and power, and industrial automation.


          Basic Features

          ● Double conversion true online design, using digital technology UPS with perfect protection function and high reliability;

          1.The inverter adopts the full digital vector control technology of dual DSP, MCU and DDC real-time processing,?

          to accurately control the parameters of the 1747208778184787.jpgmachine and conduct comprehensive control over it.

          2.Advanced IGBT high-frequency pulse width modulation technology (PWM) is combined to reduce system noise?

          and power loss, and ensure that customers can obtain high quality voltage output and the highest benefit in?

          various working load states.

          3.Double conversion, pure online sine wave output, no matter in the mains mode or battery mode, can output

          low distortion pure sine wave power supply, to provide the best power supply guarantee for the user's load?

          equipment.

          4.Output belt isolation transformer to ensure the full isolation of load and public power grid. The machine?

          equipped with isolation transformer will not appear DC components in the load, can effectively protect the?

          computer, the switching power supply of network and communication equipment is not damaged by DC?

          current, at the same time, for the nonlinear load, can also show excellent dynamic performance, improve?

          the load capacity of the machine, and the load compatibility is good.

          5.Automatic frequency / phase synchronization function to avoid the impact of input frequency hopping on the device.

          6.Perfect protection function, with AC input overvoltage, low voltage protection, output overvoltage low voltage protection, output overload short circuit protection, battery low voltage warning protection, overtemperature protection, so as to greatly ensure the stability and reliability of the system operation.

          7.The use of high-power IGBT devices makes the inverter have a strong overload capacity and impact resistance, and enhances the adaptability to the power grid.

          8.Intelligent speed regulating fan, low noise and energy saving

          9.Chinese and English LCD operation interface, more convenient management.

          ● Flexible parallel machine technology is suitable for different loads of the system single machine, 1+1 parallel machine, N+1 parallel machine operation;

          Make the parallel UPS in a relatively independent working state, intelligently, quickly and accurately to the best (phase difference<0.50), dynamic implementation of the load active and reactive power, and realize the precise load evenly, from the fault UPS system accurately and reliably, ensure that the parallel system continues to provide high quality ac power supply, the parallel system UPS circulation is almost zero, the current imbalance is less than 2%.

          Multi-machine parallel system: allows users to realize parallel operation of up to eight UPS in key applications. Advanced monitoring and high DSP digital control technology make the parallel system as simple as single machine. All UPS are equal, and there is no master-slave relationship, which is real equality. If you buy a single such UPS, you can easily expand to a "1 + 1" dual parallel machine when you need to expand or improve your reliability, or continue to expand to an N + X multi-machine redundancy system.

          ● The parallel machine can share the battery pack

          Greatly convenient for users to use, and for users to save costs.

          ● Intelligent battery management mode

          The intelligent battery charge and discharge mode and management mode can effectively improve the battery life, and matching the corresponding components can accurately calculate the battery discharge time, convenient for user management.

          ● The system has undergone strict short circuit test and 2KV high voltage insulation test;

          ● Full digital control technology, so that the whole machine control is accurate, fast, reliable and stable;

          ● Twelve pulses or active filter to effectively correct the input power factor and prevent the UPS to pollute the power grid;

          ● Powerful intelligent monitoring function, can provide RS232, RS485, dry contact point and parallel machine interface;

          UPS power supply environment monitoring system, with the international leading technology level, has developed intelligent single and network integration real-time monitoring management software, providing users with professional, perfect, practical, safe and reliable power monitoring scheme, so that intelligent network quickly and reliably manage UPS system. UPS centralized monitoring and management software can monitor UPS worldwide, integrating point-to-point to-point, point-to-many, multi-to-point, many-to-many full-function network topology structure, forming a huge intelligent UPS power network monitoring and management system.

          Features of the real-time monitoring software:

          1. Real-time monitoring for single users;

          2. Real-time monitoring for the centralized management of large-scale WAN.

          ● Flexible networking scheme

          RS232, RS485, dry contact, SNMP card, Modem can meet TCP / IP protocol and adapt to LAN, WAN and INTERNET network monitoring.

          1. The RS232 serial communication interface is connected one to one, which is directly connected with the RS232 communication port of the computer, realizing the two-way data exchange, remote monitoring and intelligent management in close distance (<100m) between the computer and UPS equipment.

          2. RS485 adopts advanced balance circuit, improved interface RS485 serial communication standard, duplex communication mode, one-to-one connection. Dedicated RS485 / RS232 interface converter is connected to the communication interface of RS232 of the computer and connected to the computer through a cable to support data transmission at high speed and distance (<1200mm).

          3, SNMP network card adopts the world's popular Ethernet technology, advanced TCP / IP network protocol, duplex communication mode, many-to-many connection. UPS built-in or external dedicated SNMP network card connects with computer-configured network card to realize intelligent monitoring of<100m; it is also connect to the LAN to implement networked monitoring of one (or multiple) UPS.

          4. UPS built-in Modem can dial through the telephone line to the local telephone network, call the landline, mobile phone, prompt the UPS abnormal state: bypass, shutdown, battery low voltage, overload, etc.

          5. The UPS dry contact alarm signal conducts long-distance alarm through the contact closure, connects the remote indicator light, electric bell and relay execution unit, prompting no city power, battery low voltage, machine fault, etc.


          Technical Specifications


          (I) Rectifier input and output parameters

          1.Rectifier input parameters

          Model

          10kVA

          20kVA

          30kVA

          40kVA

          60kVA

          80kVA

          100kVA

          120kVA

          160kVA

          200kVA

          250kVA

          300kVA

          400kVA

          500kVA

          600kVA

          Nominal capacity (kW)

          8

          16

          24

          32

          48

          64

          80

          96

          128

          160

          200

          240

          320

          400

          480

          Single-phase maximum input

          19

          38

          57

          76

          114

          152

          190

          228

          304

          379

          475

          570

          760

          950

          1140

          current (A)

          Working mode and principle

          Online ??power supply, static bypass switch (no intermittent switching), dual ??conversion technology, the output power supply is

          completely ??isolated

          Input power factor

          0.8/0.9(12 pulses)/0.95(with ????active filter)

          Number of phases

          Three-phase+N+G

          Nominal voltage

          380VAC±25%

          Nominal frequency

          50/60Hz±10%

          Input current harmonics

          <5%

          Soft start

          0~100%5sec

          2.rectifier output ?parameters

          Model

          10kVA

          20kVA

          30kVA

          40kVA

          60kVA

          80kVA

          100kVA

          120kVA

          160kVA

          200kVA

          250kVA

          300kVA

          400kVA

          500kVA

          600kVA

          Maximum output voltage (VDC)

          432V

          648V

          The microcomputer sets the

          6~30A(adjustable)

          charging current

          (2) Battery

          Model

          10kVA

          20kVA

          30kVA

          40kVA

          60kVA

          80kVA

          100kVA

          120kVA

          160kVA

          200kVA

          250kVA

          300kVA

          400kVA

          500kVA

          600kVA

          Maximum discharge current (A)

          28

          56

          85

          113

          169

          225

          282

          338

          461

          576

          700

          840

          1120

          1400

          1120

          Number of batteries per group

          12V32pcs or 2V192pcs

          12V48pcs

          Nominal battery voltage

          384VDC

          576VDC

          Floating charge voltage

          432VDC

          648VDC

          Charging current

          6~30A(adjustable)

          (3) Inverter

          Model

          10kVA

          20kVA

          30kVA

          40kVA

          60kVA

          80kVA

          100kVA

          120kVA

          160kVA

          200kVA

          250kVA

          300kVA

          400kVA

          500kVA

          600kVA

          Power rating (kW)

          8

          16

          24

          32

          48

          64

          80

          96

          128

          160

          200

          240

          320

          400

          480

          Number of phases

          Single-phase or three-phase+N+G

          three-phase+N+G

          Nominal voltage

          220/380VAC±1% (steady state)

          380VAC±1% (steady state)

          Nominal frequency

          50/60Hz±0.5% (battery mode)

          Output power factor

          0.8/0.9

          Frequency stability

          <±0.5% (when out of ????synchronization)

          <±2% (when synchronized ????with mains)

          Crest factor

          3:1

          Discharge waveform

          sinusoidal wave

          Total harmonic distortion

          Linear ??load<3%; ??nonlinear load <5%

          Dynamic load voltage transient

          <4%

          Moment recovery time

          <10ms

          Balanced load voltage

          <± 1%;<5% (unbalanced ??negative hub)

          Overload capacity

          125%30min,150%1min,>150%300ms

          Inverter efficiency (load of?100%)

          >93%

          >96%

          (4) Bypass

          Model

          10kVA

          20kVA

          30kVA

          40kVA

          60kVA

          80kVA

          100kVA

          120kVA

          160kVA

          200kVA

          250kVA

          300kVA

          400kVA

          500kVA

          600kVA

          Number of phases

          Single-phase or three-phase+N+G

          Three-phase+N+G

          Nominal voltage

          380VAC±15%

          Nominal frequency

          50/60Hz±10%

          Transfer time

          0ms

          (5) System

          Model

          10kVA

          20kVA

          30kVA

          40kVA

          60kVA

          80kVA

          100kVA

          120kVA

          160kVA

          200kVA

          250kVA

          300kVA

          400kVA

          500kVA

          600kVA

          Computer communication

          interface

          RS232, RS485, dry contact, smart ??slot

          Running temperature

          0~40

          Relative humidity

          0%~90% ?(no condensation)

          Operating height(max.)

          <1000m (1% for 100m, maximum ??4000m)

          Cooling-down method

          Forced draft

          Noise

          48~65dB

          53~68dB

          60~75dB

          MTBF

          300000 Hours

          Levels of protection

          IP20

          Box color

          Black(optional white)

          Input cord

          Bottom/back

          Easy to maintain

          Front/ top/side

          Outline dimension (mm)

          D

          685

          760

          800

          880

          1050

          W

          360

          360

          660

          900

          1550/2250(12 pulses)

          H

          825

          990

          1550

          1650

          1900

          Reference Weight (kg)

          128

          175

          230

          280

          380

          550

          650

          700

          850

          900

          1050

          1500

          1700

          1900

          2300

          Input equipment

          Terminal row

          Output equipment

          Terminal row

          Note: Customizable output power PF=0.9.

          * The above parameters may be adjusted and changed, please refer to the physical object